Spike series · SPIKE135
135kVA
Replaces the site genset for tower cranes and hoists: the battery absorbs the motor inrush a diesel would be oversized for.

Storage platform
SiC + liquid cooling
- Rated energy
- 54 kWh
- Peak (10 s)
- 160 kVA
- Rated current
- 195 A @ 400 V
- Response
- <15 ms
Applications
Tower cranesHoistsPlacing boomsStatic pile driversDTH drillsMine elevatorsOne complete system
Everything in one cabinet.
Battery, power conversion, control and protection arrive as one engineered unit: place it, connect it, power up.
835 V battery
High-voltage pack rated for 4,000 cycles at 90% depth of discharge and 70% end-of-life capacity.
3rd-gen SiC inverter
<15 ms response with constant P/I/V control and Black Start capability for standalone operation.
Dual-side liquid cooling
Variable-frequency cooling holds cell temperature spread within 3 °C, extending cell life by up to 30%.
Site-proof connections
CEE and Powerlock interfaces in an IP54 enclosure with a C4 salt-fog rating for coastal sites.

Spike series containerised enclosure
The inrush
Peaks arethe point.
Lifting motors draw multiples of their rated current at start. The Spike 135 answers with 160 kVA for ten seconds and up to 231 A peak, then settles back to a steady 135 kVA, recharging from a small feed between lifts.
- Peak (10 s)
- 160 kVA
- Peak current
- 231 A @ 400 V
- 5-min output
- 145 kVA
- Recharge
- 30 kW · 3-ph
At a glance
Built for the site.
The physical details that matter for transport, placement and connection.
Weight
1,550 kg ±50
Dimensions
1550 × 1300 × 1600 mm
Enclosure
IP54 · C4 salt fog
Warranty
5 years
Available configuration
AC-DC fast charger (20-40 kW three-phase)
Three-phase fast charger for BESS units, used to recharge from grid or generator.
On-board charger (OBC), 6.6 kW single-phase
Optional single-phase overnight charger for Spike/Block series.
Datasheet
Technical specifications.
SPIKE135
Battery
- Rated energy
- 54 kWh
- Rated voltage
- 835 V
- Voltage range
- 728 – 949 V
- Cycle life
- 4,000 · 90% DoD & 70% EOL
AC input · charging
- Single-phase power
- 6.6 kW (optional)
- Single-phase voltage / current
- 85 – 264 V · max. 32 A
- Three-phase power
- Max. 30 kW
- Three-phase voltage / current
- 260 – 530 V (3P3W) · max. 40 A
- Frequency
- 50 / 60 Hz
AC output
- Rated output power
- 135 kVA
- Apparent power (5 min)
- 145 kVA
- Peak power (10 s)
- 160 kVA
- Rated output current
- 195 A @ 400 V · 162.5 A @ 480 V
- Max. output current (5 min)
- 210 A @ 400 V · 175 A @ 480 V
- Max. peak current
- 231 A @ 400 V · 192 A @ 480 V
- Rated output voltage
- 400 / 480 V · 3L/N/PE
- Frequency
- 50 / 60 Hz
- THDi
- ≤3%
- Power factor
- 0.99 · −1 to 1
General
- Dimensions (L×W×H)
- 1550 × 1300 × 1600 mm
- Weight
- 1,550 kg ±50
- Input interface
- CEE 32 A (1P3W) · CEE 63 A (3P3W)
- Output interface
- CEE 32 A · CEE 63 A (3P5W) · Powerlock 400 A
- Display
- 10-inch HMI
- Communication
- Dry contact · Bluetooth · Wi-Fi · 4G
- Warranty
- 5 years
- Enclosure
- IP54 · C4 salt-fog rating
- Cooling
- Liquid cooling
- Operating temperature
- −20 to +60 °C
- Relative humidity
- 10 – 95% non-condensing
- Installation
- Hoisting & ground fastening
Next step