Spike series · SPIKE270
270kVA
Twin-crane sites and heavy lifting gear on one battery: 320 kVA of ten-second headroom without a big diesel on standby.

Storage platform
SiC + liquid cooling
- Rated energy
- 108 kWh
- Peak (10 s)
- 320 kVA
- Rated current
- 390 A @ 400 V
- Response
- <15 ms
Applications
Tower cranesHoistsPlacing boomsStatic pile driversDTH drillsMine elevatorsOne complete system
Everything in one cabinet.
Battery, power conversion, control and protection arrive as one engineered unit: place it, connect it, power up.
835 V battery
High-voltage pack rated for 4,000 cycles at 90% depth of discharge and 70% end-of-life capacity.
3rd-gen SiC inverter
<15 ms response with constant P/I/V control and Black Start capability for standalone operation.
Dual-side liquid cooling
Variable-frequency cooling holds cell temperature spread within 3 °C, extending cell life by up to 30%.
Site-proof connections
CEE and Powerlock interfaces in an IP54 enclosure with a C4 salt-fog rating for coastal sites.

Spike series containerised enclosure
The inrush
Peaks arethe point.
Lifting motors draw multiples of their rated current at start. The Spike 270 answers with 320 kVA for ten seconds and up to 462 A peak, then settles back to a steady 270 kVA, recharging from a small feed between lifts.
- Peak (10 s)
- 320 kVA
- Peak current
- 462 A @ 400 V
- 5-min output
- 290 kVA
- Recharge
- 40 kW · 3-ph
At a glance
Built for the site.
The physical details that matter for transport, placement and connection.
Weight
2,200 kg ±50
Dimensions
1550 × 2050 × 1600 mm
Enclosure
IP54 · C4 salt fog
Warranty
5 years
Available configuration
AC-DC fast charger (20-40 kW three-phase)
Three-phase fast charger for BESS units, used to recharge from grid or generator.
On-board charger (OBC), 6.6 kW single-phase
Optional single-phase overnight charger for Spike/Block series.
Datasheet
Technical specifications.
SPIKE270
Battery
- Rated energy
- 108 kWh
- Rated voltage
- 835 V
- Voltage range
- 728 – 949 V
- Cycle life
- 4,000 · 90% DoD & 70% EOL
AC input · charging
- Single-phase power
- 6.6 kW (optional)
- Single-phase voltage / current
- 85 – 264 V · max. 32 A
- Three-phase power
- Max. 40 kW
- Three-phase voltage / current
- 260 – 530 V (3P3W) · max. 63 A
- Frequency
- 50 / 60 Hz
AC output
- Rated output power
- 270 kVA
- Apparent power (5 min)
- 290 kVA
- Peak power (10 s)
- 320 kVA
- Rated output current
- 390 A @ 400 V · 325 A @ 480 V
- Max. output current (5 min)
- 420 A @ 400 V · 350 A @ 480 V
- Max. peak current
- 462 A @ 400 V · 385 A @ 480 V
- Rated output voltage
- 400 / 480 V · 3L/N/PE
- Frequency
- 50 / 60 Hz
- THDi
- ≤3%
- Power factor
- 0.99 · −1 to 1
General
- Dimensions (L×W×H)
- 1550 × 2050 × 1600 mm
- Weight
- 2,200 kg ±50
- Input interface
- CEE 32 A (1P3W) · CEE 63 A (3P3W)
- Output interface
- CEE 32 A · CEE 63 A (3P5W) · Powerlock 630 A
- Display
- 10-inch HMI
- Communication
- Dry contact · Bluetooth · Wi-Fi · 4G
- Warranty
- 5 years
- Enclosure
- IP54 · C4 salt-fog rating
- Cooling
- Liquid cooling
- Operating temperature
- −20 to +60 °C
- Relative humidity
- 10 – 95% non-condensing
- Installation
- Hoisting & ground fastening
Next step
Start with your load.
Share the load profile, duty cycle and site conditions. We will size the storage, charging feed and any generator pairing.